PATIENT MONITOR - SAADAT - MALAYSIA

PATIENT MONITOR - SAADAT - MALAYSIA


PATIENT MONITOR
MERK : SAADAT - MALAYSIA
MODEL : ALBORZ B9
Specifications : DISPLAY Displaying Color LED 1366 x 768,18.5" Printing Speed 12.5, 25, 50 mm/sec Operation Method Rotary Knob & Membrane ECG : Leads : 3/5 leads Dynamic Range : ± 5 mV Leakage Current : < 10µA Lead Off Cureent : < 90 nA Gain : 4, 2, 1, 1/2, 1/4, Auto Calibration : 1mV, 0.5 sec Filters : "MONITOR" ( 0.5 - 24Hz ) "NORMAL" ( 0.5 - 40 Hz ) "EXTENDED" ( 0.05 - 100 Hz ) CMRR : > 98dB Internal Noise : < 30 µV RTI Input Impedance : > 5 Mohm QRS Detection : Duration : 40 to 120 msec Amplitude : 0.25 to 5 mV for Adult 0.2 to 5 mV for Neonate Heart Rate Range : 15 - 300 bpm for Adult 15 - 350 bpm for Neonate Accuracy : ±1% or 2 bpm Tall T-wave : Reject up to 1.2 mV Amp. Pace Detection / Rejection : Duration : 0.1 - 2 msec Amp : ± 2 to ± 700 mV ( Without over/undershoot ) Reject From Heart Rate Counter Re-insert into ECG to display on screen Protection : Defibrillator and Electro surgery Standards : ANSI / AAMI EC - 13 ARRHYTHMIA ANALYSIS : Type : ASYS, VFIB, VTAC, RUN, AIVR, COUPLET, BIGEMINY, TRIGEMINY, TACHY, BRADY, PAUS, FREQUENT PVCs Learning : Rapid Learning : only 20 Second Required or Recognition of Dominant Rhythm Methode : Real Time Arrhythmia Detction with Innovative Feature. Memory : Capability of storing the latest 80 ARR event. ( waveform and parameters ) ST ANALYSIS : Display resolution : 0.01 mV D E S C R I P T I O N Page 2 NO D E S C R I P T I O N Measurement Range : -2 mV to +2mV Alarm Range : -2 mV to +2 mV Features : User Adjustable Isoelectric and ST Point Trending of ST Values Update period : 5 sec. Masimo SET SPO2 Method : 2 wave Length Pulse Wave Type Range : 50% to 100% Accuracy : ± 2% (SPO2 71 ~ 100%) : ± 3% (SPO2 50 ~ 70%) Pulse Rate Range : 25-250 bpm NIBP : Measurement methode : Oscillometric Measurement mode : Manual/ Automatic ( intervals between 5min - 24hour ) / STAT Measurement time : 18-26 sec ( excluding cuff pressurization time ) Measurement Range : Adult : SYS 25 ~ 250 mmHg DIA 10 ~ 220 mmHg MAP 15 ~ 250 mmHg Neonate : SYS 25 ~ 135 mmHg DIA 10 ~ 110 mmHg MAP 15 ~ 125 mmHg Pressure Transducer accuracy : ±3 mmHg full range Initial Inflation Target : Adult 150 mmHg , Neonate 70 mmHg Overall System Efficacy : Meet ANSI / AAMI SP-10/1992 Memory : Up to 100 Records RESPIRATION : Method : Impedance Base Resistance : 250 - 1250 Ohm Dynamic Range : 0.2 - 2 Ohm Breath Rate Range : 6 - 150 BrPM TEMPERATURE : Probe Type : YSI 700 Compatible Range : 0 - 50 °C Accuracy : ±0.2 °C ALARM : Sources : Error messages,all other Parameter Limits Alarm On / Off : Selectable for All Parameters Alert : Blinking on Display, Volume Selectable Audio Alarms,Light indicator INPUT / OUTPUT Network : Ethernet LAN Page 3 NO D E S C R I P T I O N Connection : Up to 16 BEDs to one CENTRAL GENERAL : Safety : Based on IEC 60601-1 Protection : Against Electro surgery and Defibrillator AC power : 90 - 260 VAC,50/60 Hz Internal Battery : Li-ion or (Sealed Lead Acid) Rechargeable 12 V, 5.0 AH (3.3AH) Charge time 16 Hours Usage more than 4 hours ( 2 hours ) DC Power Plug : 12 - 14V - 3A / ( 6A with recorder ) Dimension ( Cm ) : 45 (W) x 35 (H) x 16 (D) Nett weight : 5.5 to 7.5 Kg RECORDER Model : Thermal Printer Printing Speed: 12.5, 25, 50 mm/sec. Paper : 58 mm by 100 foot roll ENVIRONMENTAL : Temperature : Operating 5 to 40°C Storage : -20 to 60°C Humidity : 20 - 90% ( Non condensing ) Altitude : -200 to 3000m All specifications are subject to modifications and improvements without prior notice

Posting Komentar

 
Support : Creating Website | Johny Template | Mas Template
Copyright © 2011. Distributor Alat Kesehatan dan Alat Kedokteran - All Rights Reserved
Template Created by Creating Website Published by Mas Template | Distributed By: BloggerBulk
Proudly powered by Blogger